Grand Central Vac TRUE CYCLONIC® System Specifications

PERFORMANCE

260

The perfect choice for homes up to 3,000 square feet

466Q

The perfect choice for homes up to 5,000
square feet

566Q

The perfect choice for homes up to 8,000
square feet


Sealed Vacuum (H20 lift)

106"

121"

135"

CFM Max

110

114

118

Max Air Watts*

443

477

535

Volts

120

120

120

Max/Avg Amps**

12.6/10.5

14.9/11.6

15.6/12.0

Level of Quietness dB***

70.1 dBA

59.7 dBA

60.7 dBA

FEATURES


Filtration

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

Collection Capacity

5.5 gallons

6 gallons

6 gallons

Low Voltage Controls

24 V PC Board

24 V PC Board

24 V PC Board

Overload Heat Protection

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Warranty

Lifetime Limited +3

Lifetime Limited +3

Lifetime Limited +3

Construction

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

Dimensions/Weight

12 5/8" dia. x 36 3/8" high / 26 pounds

12 5/8" dia. x 38 7/8" high / 28 pounds

12 5/8" dia. x 40 1/4" high / 31 pounds

INSTALLATION


Electrical Requirements

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

Mounting Requirements

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Exterior Venting

Single exhaust muffler included

Single exhaust muffler included

Single exhaust muffler included




back to top


* ASTM recognizes air watts as air power and is defined as "above the floor cleaning potential."

** Maximum amps refer to the potential amount of current if the power unit is running in a stand-alone situation. (no tubing or accessories attached). Average amps refer to the actual amount of current used when the power unit is in typical operation (installed, with accessories attached).

*** ASTM draft F11.50.07 test method was used to determine dBA ratings. Sound levels were measured at 6' from the power unit. All power units were exhausted outdoors.